prtmib — SNMPv2c printer marker dump prtmib [-v] One UDP GET per host listed in config.h. Prints a dense table of the values the device actually returned. No JSON, no daemon, no layout flags. Filter with grep(1). Columns idx index in the printers[] table (config.h) host FQDN with trailing .obspm.fr stripped ms round trip, milliseconds err SNMP error-status (0 = noError); RFC 1905 names with -v up sysUpTime as days+hours+minutes hrDev hrDeviceStatus hrPrt hrPrinterStatus eflags hrPrinterDetectedErrorState bits that are set pages prtMarkerLifeCount, else kmLifeCount, else xrxImpressions toner Y/M/C/K percent, letters taken from prtMarkerSuppliesDescription (not slot index). Order matches Konica PageScope (Yellow, Magenta, Cyan, Black). F_XRX is a tag only. Else Konica enterprise OIDs. '*' = <= LOWPCT, '!' = <= CRITPCT src which mapping filled toner: std | xrx | km | - model sysDescr up to ';' (Xerox firmware blob stripped), trailing " vN" dropped, then truncated -v also prints every varbind (OID, MIB name, BER tag, value) and a short packet trace. Exit status 0 every host answered a parseable GetResponse 1 at least one DNS failure, timeout, or bad PDU 2 usage Build Windows (MinGW, default config.mk): make as(1) and ld(1) must be the MinGW ones; config.mk prepends MINGWBIN to PATH so a stock prompt is enough. Linux: edit config.mk (comment the Windows block, uncomment Linux), then make. `RM = rm -f` on Unix. Hosts, community, timeouts, thresholds: config.h. Recompile. Protocol SNMPv2c GET, UDP/161. One PDU per host carrying sysDescr, sysName, sysUpTime, hrDeviceStatus, hrPrinterStatus, hrPrinterDetectedErrorState, prtMarkerLifeCount, supplies description/max/level 1-4, Konica 18334 page+toner OIDs, Xerox 253 impressions. Missing objects arrive as noSuchObject / noSuchInstance. Standard supply indices are CMYK. Konica enterprise indices are KCMY. Supply -1/-2/-3 (other/unknown/some) are not treated as percentages.